Packaged Fire Pump System End Suction Diesel Engine Fire Pump with Nfpa Standard

Product Details
Customization: Available
After-sales Service: Remote Guidance
Warranty: One Year for Pump, Three Month for Spare Parts
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500000 RMB
Plant Area
501~1000 square meters
  • Packaged Fire Pump System End Suction Diesel Engine Fire Pump with Nfpa Standard
  • Packaged Fire Pump System End Suction Diesel Engine Fire Pump with Nfpa Standard
  • Packaged Fire Pump System End Suction Diesel Engine Fire Pump with Nfpa Standard
  • Packaged Fire Pump System End Suction Diesel Engine Fire Pump with Nfpa Standard
  • Packaged Fire Pump System End Suction Diesel Engine Fire Pump with Nfpa Standard
  • Packaged Fire Pump System End Suction Diesel Engine Fire Pump with Nfpa Standard
Find Similar Products

Basic Info.

Model NO.
XBC/DA
Flow Rate
Constant Pump
Type
Centrifugal Pump
Drive
Electric or Diesel Engine
Performance
High Pressure
Color
Red
Sealing Type
Packing Seal or Mechanical Seal
Voltage
220V/380V/400V/415V/460V
Material
Cast Iron/SS304/SS316
Usages
Fire Fighting
Working Temperature
Normal
Pump Spare Parts
Pump Casing, Impeller, Seal, Coupling, Bearing
Speed
1450/1750/2900/3500rpm
Standard
UL, Nfpa20
Transport Package
Exporting Plywood Case
Specification
CE, ISO
Trademark
DEFU
Origin
China
HS Code
8413709990
Production Capacity
10000PCS/Year

Product Description

1.Product Description

EDJ series is a packaged fire pump set,generally an automatic fire water supply system It consists of a main pump (driven by an electrical motor),stand by pump (driven by diesel engine) and a jockey pump.This model comes equipped with a separate controller,or one that is attached to the skid,The package also contains discharge valves,common header,and accessories.


2.Working Principle

Generally the pipeline network's pressure is between the low pressure P1 and the high pressure P2.When the above  pressure is lower than P1,the pressure maintaining pump will start automatically and not stop until the pressure rises gradually to P2.Due to the pipeline network's leakage,its pressure will drop to P1 gradually,and then the pressure maintaining pump will start automatically again.with such a repeated process,the pipeline network's pressure is maintained between P1 and P2 all the time.when the pipeline network's pressure can't be maintained between P1 and P2 (for instance,when the water consumption increases a lot) and drops to the minimum pressure P3,the electric pump will start automatically and the pressure will rise to Pw and meet the need for fire water supply,if the mains supply is power-off or the electric pump fails,the pressure will continue to drop from P3 to the ultimate pressure P4.then the diesel pump set will start automatically,and the pressure will rise to Pw and meet the need for fire water supply.the electric or diesel pump shall be stopped manually after human judgment (except automatic switching ).
 

3. Fire Pump Package Pump Specifications Choosing(More Information pls feel free to contact us)

Electrical+Diesel+Jockey Fire Pump 

Diesel Pump Choosing

GPM

Diesel Pump, 250GPM, 8 Bar, 2950RPM

Diesel Engine, 220V/1PH/50HZ

Per set components: Diesel Pump, Control Cabinet, Flow meter and other accessories

250 GPM

Diesel Pump, 350GPM, 8 Bar, 2950RPM

Diesel Engine, 220V/1PH/50HZ

Per set components: Diesel Pump, Control Cabinet, Flow meter and other accessories

350 GPM

Diesel Pump, 500GPM, 8 Bar, 2950RPM

Diesel Engine, 220V/1PH/50HZ

Per set components: Diesel Pump, Control Cabinet, Flow meter , Pressure Relief Valve,

Drain Window and other accessories

500 GPM

Diesel Pump, 750GPM, 10 Bar, 2950RPM

Diesel Engine, 220V/1PH/50HZ

Per set components: Diesel Pump, Control Cabinet, Flow meter , Pressure Relief Valve,

Drain Window and other accessories

750 GPM

Diesel Pump, 1000GPM, 10 Bar, 2950RPM

Diesel Engine, 220V/1PH/50HZ

Per set components: Diesel Pump, Control Cabinet, Flow meter , Pressure Relief Valve,

Drain Window and other accessories

1000 GPM

Electric Motor Pump Choosing

Motor Pump, 250GPM, 8 Bar, 2950RPM

Motor, 40HP, 3-phase, 50HZ, 380V

Per set components: Motor Pump, Control Cabinet and otheraccessories

250 GPM

Motor Pump, 350GPM, 8 Bar, 2950RPM

Motor, 50HP, 3-phase, 50HZ, 380V

Per set components: Motor Pump, Control Cabinet and other accessories

350 GPM

Motor Pump, 50GPM, 8 Bar, 2950RPM

Motor, 75HP, 3-phase, 50HZ, 380V

Per set components: Motor Pump, Control Cabinet and other accessories

500 GPM

Motor Pump, 50GPM, 10 Bar, 2950RPM

Motor, 100HP, 3-phase, 50HZ, 380V Per set c


1000 GPM
 

4.Applictaions(Show from our clients)

Packaged Fire Pump System End Suction Diesel Engine Fire Pump with Nfpa Standard

5.Our Services

1. Delivery: Delivery time will be on time as the contract. Usually, our company need 25 working  days for diesel engine pump, and for bare shaft pump, it takes 15 working days,

2. Warranty: 12 month for the pump body, 3 month for the main working parts.

3. Package: We use plywood case to pack our pump, which is durable for ocean transport.

4. On-sales Service: we will clear show you everything in fact when you place an order with us. We will
take photos or videos to show you our production situation, and report the production situation to you.

5. Quality: we will test our pump before delivery, and we will follow up the pump working conditions per three months when the pump put into use. If you need spare parts, we can send to you in 1 or 2 weeks.


6.Our Factory

Packaged Fire Pump System End Suction Diesel Engine Fire Pump with Nfpa Standard

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier